Hybrid Inverter SL-D3-8KTL-H30
97.6% Max. Efficiency
15A PV Input Current
30A Charge/Discharge
10ms UPS-level Switch
Parameter List
Model | SL-D3KTL-H30 | SL-D4.2KTL-H30 | SL-D6KTL-H30 | SL-D8KTL-H30 |
PV Input | ||||
---|---|---|---|---|
Recommended Max. input power (kW) | 4.80 | 6.72 | 9.60 | 12.80 |
Start-up voltage (V) | 80 | 80 | 80 | 80 |
Max. DC input voltage* (V) | 600* | 600* | 600* | 600* |
Rated DC input voltage (V) | 360 | 360 | 360 | 360 |
MPPT voltage range* (V) | 100-550* | 100-550* | 100-550* | 100-550* |
No. of MPP trackers | 1 | 2 | 2 | 2 |
No. of DC inputs per MPPT | 1 | 1/1 | 1/1 | 1/1 |
Max. input current (A) | 15 | 15/15 | 15/15 | 15/15 |
Max. short-circuit current (A) | 20 | 20/20 | 20/20 | 20/20 |
Battery Side | ||||
Battery type | Lithium Battery (with BMS) | |||
Battery voltage range (V) | 85-450 | |||
Maximum charging/discharging current (A) | 30/30 | |||
Grid Side | ||||
Rated output power (kW) | 3.00 | 4.20 | 6.00 | 8.00 |
Max. output apparent power (kVA) | 3.30 | 4.60 | 6.60 | 8.00 |
Max. input apparent power** (kVA) | 6.00 | 8.40 | 10.00 | 12.00 |
Max. charging power of battery (kW) | 3.00 | 4.20 | 6.00 | 8.00 |
Rated AC voltage | L/N/PE: 220/230/240V | |||
Rated AC frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
Max. output current (A) | 15.00 | 21.00 | 28.70 | 36.30 |
Power factor | 0.8 leading ...0.8 lagging | |||
Max. total harmonic distortion | <3% @Rated output power | |||
DCI | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Back-up Side | ||||
Rated output power (kW) | 3.00 | 4.20 | 6.00 | 8.00 |
Max. output apparent power (kVA) | 3.30 | 4.60 | 6.60 | 8.00 |
Max. output current (A) | 15.00 | 21.00 | 28.70 | 36.30 |
UPS switching time | <10ms | <10ms | <10ms | <10ms |
Rated output voltage | L/N/PE:220/230/240V | |||
Rated output frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
Voltage harmonic distortion | <3% @Linear load | |||
Efficiency | ||||
Max. efficiency | 97.6% | 97.6% | 97.6% | 97.6% |
European efficiency | 97.0% | 97.0% | 97.0% | 97.0% |
* PV Max. Input voltage is 550V without battery, or 500V with battery, otherwise inverter will be waiting;
** Max apparent power from the grid means the maximum power imported from the utility grid used to satisfy the backup clads and charge the battery;
1)G98: 3.68A;2) G98: 16.00A;3) AS 4777.2: 50kW,VDE-AR-N 4105: 4.6kW;4)AS 4777.2: 5.0kVA,VDE-AR-N 4105: 4.60kVA;C10/11: 5.0kVA;5) AS 4777.2: 21.7A;VDE-AR-N 4105: 21.0A;C10/11: 21.7A;
Protection | |
DC reverse polarity protection | Integrated |
Battery input reverse connection protection | Integrated |
Insulation resistance protection | Integrated |
Surge protection | Integrated |
Over-temperature protection | Integrated |
Residual current protection | Integrated |
Islanding protection | Integrated |
AC over-voltage protection | Integrated |
Overload protection | Integrated |
AC short-circuit protection | Integrated |
General Data | |
Over voltage category | PV: Ⅱ Main: Ⅲ |
Dimensions (W×H×D mm) | 534×418×210 |
Weight (kg) | 27.0 |
Protection degree | IP65 |
Standby self-consumption (W) | <15 |
Topology | Transformerless |
Operating Temperature Range (°C) | -30-60 |
Relative Humidity (%) | 0-100 |
Operating Altitude (m) | 3000 (>3000m derating) |
Cooling | Natural Convection |
Noise Level (dB) | <25 |
Display | OLED & LED |
Communication | CAN.RS485.WiFi/LAN (Optional) |